Author:
Parker ssd Control cabinet
Parker Eurotherm Drives Application
Parker 690 AC Drives
The AC690+ Integrator Series is a single range of AC drives designed to meet the requirements of all variable speed applications from simple single motor speed control through to the most sophisticated integrated multi-drive systems. The heart of the AC690+ is a highly advanced 32-bit microprocessor based motor control model. This provides an exceptional dynamic performance platform to which can be added a host of communications and control options, enabling you to tailor the drives to meet your exact requirements. The AC690+ is available in 380V-500V 3-phase 0.75KW to 1000 KW and 220V-240V 0.75KW to 55KW.
Technical Specification
Power supply
380-460V (±10%) 3-phase 0.75KW to 1000kW ;
380-500V (±10%) 3-phase 2.2KW to 110kW;
220-240V (±10%) 1-phase 0.37KW to 2.2kW;
220-240V (±10%) 3-phase 0.37KW to 37 kW.
Output current value (A)
2.5A – 1700A
Output power rating (KW)
0.75KW – 1000KW
COMMUNICATION INTERFACE
RS232 / RS485 | Modbus |CANopen | ControlNet | Profibus |
OPERATING TEMPERATURE (C)
0-45C / 0-40C with IP40 cover / derate up to 50C max
OPERATING TEMPERATURE (F)
32-113F/ 32-104F with IP40 cover(derate up to 122F max)
OPERATING CONTROL MODES
V/Hz | Sensoriess Vector | Closed Loop Vector
690 AC Drives Applications:
• Water and wastewater
• Paper and pulp processing
• Steel
• Marine and offshore
• Outdoor cranes
• Wind & wave power generation
• Food processing.
Parker 690 AC Drives Frame:
Parker 650 Series AC Drives
The Parker AC650G is an entry level adjustable speed drive designed to provide cost-effective control of AC induction motors used in many everyday industrial applications. Its simplicity makes the AC650G ideally suited for use in standalone motor applications where previously a drive would have been considered too complex.
The AC650G is ideally suited to energy saving in pump and fan applications and delivers reliable, cost-effective voltage/frequency or sensorless vector speed control of your motor.
To prevent unauthorized changes to drive configuration after setup, the operator/programming keypad can be removed or password protected.
The AC650G is an easy to use, out of the box solution that will have your system up and running in record time. It provides reliable, robust motor control from 0.3 HP through 10 HP.
Electrical Characteristics
Power supply
230V AC Single phase | 230V AC Three phase | Three phase 380V…460V
Input frequency 45…65 Hz
Output frequency 0…240 Hz
COMMUNICATION INTERFACE RS232 / RS485…
CERTIFICATES CE (EMC & LVD) | cUL Listed
Environmental Characteristics
Operating temperature 0…40 degree
Storage Temperature -25…+55 degree
Operating Altitude Up to 1100m
Parker 890 Series AC Drives
The AC890 is a compact, modular systems drive engineered to control speed and position of open-loop and closed-loop, single- or multi-motor AC or servo motor
Parker 890 Applications:
Features
The AC890 can be configured for 4 different modes of operation
Open-loop (volts / frequency) control
This mode is ideal for basic, single or multi-motor speed control.
Sensorless vector control
With its ultra high performance sensorless vector algorithm,the AC890 delivers a combination of both high torque and close speed regulation without the need for any speed measuring transducer.
Closed-loop vector control
Full closed-loop flux vector performance can be achieved with the AC890 by simply adding an encoder feedback‘technology box’. This provides 100% continuous full load standstill torque, plus a highly dynamic speed loop more than sufficient for the most demanding applications.
Demanding environments
For environments that have dusty, humid or corrosive atmospheres, the AC890 can optionally be supplied with conformally coated circuit boards that improve the drives
resistance to corrosion, thereby increasing reliability and service life.Industries that would typically benefit from conformal coating could include :
- Water and wastewater
- Paper and pulp processing
- Steel
- Marine and offshore
- Outdoor cranes
- Wind & wave power generation
- Food processing.
Parker 890 Frame drawing:
Parker DC Drives Spare Parts & Accessories
Parker Drives Power Board and Control Board
Parker Drives 590+ Spares List (Frames 1-5 & H)
Frame 1
Product Power Board Terminal Board
591P/0015/220/ AH470280U101 AH466407U001
590P/0015/220/ AH470280U102 AH466407U001
591P/0035/220/ AH470280U103 AH466407U001
590P/0035/220/ AH470280U104 AH466407U001
591P/0015/500/ AH470280U001 AH466407U001
590P/0015/500/ AH470280U002 AH466407U001
591P/0035/500/ AH470280U003 AH466407U001
590P/0035/500/ AH470280U004 AH466407U001
Frame 2
Product Power Board Armature Thyristor
591P/0040/220/ AH470330U101* CF385522U016
590P/0040/220/ AH470330U102* CF385522U016
591P/0070/220/ AH470330U101* CF385524U016
590P/0070/220/ AH470330U102* CF385524U016
591P/0110/220/ AH470330U101* CF385525U016
590P/0110/220/ AH470330U102* CF385525U016
591P/0165/220/ AH470330U101* CF470523U095
590P/0165/220/ AH470330U102* CF470523U095
591P/0040/500/ AH470330U001* CF385522U016
590P/0040/500/ AH470330U002* CF385522U016
591P/0070/500/ AH470330U001* CF385524U016
590P/0070/500/ AH470330U002* CF385524U016
591P/0110/500/ AH470330U001* CF385525U016
590P/0110/500/ AH470330U002* CF385525U016
591P/0165/500/ AH470330U001* CF470523U095
590P/0165/500/ AH470330U002* CF470523U095
Frame 3 Fitted with the 590PXD Door Assembly LA466454U001 containing the Control Board and Adaptor Board AH466405U001
Product Power Board Armature Thyristor
591P/0180/220/ AH385851U004 CF385525U016
590P/0180/220/ AH385851U005 CF385525U016
591P/0270/220/ AH385851U004 CF057366U014
590P/0270/220/ AH385851U005 CF057366U014
591P/0180/500/ AH385851U003 CF385525U016
590P/0180/500/ AH385851U002 CF385525U016
591P/0270/500/ AH385851U003 CF057366U014
590P/0270/500/ AH385851U002 CF057366U014
Frame 4 Fitted with the 590PD Door Assembly LA466454U002 containing the Control Board
Product Power Board Suppression Board Trigger Board Thyristor
591P/0380/220/ AH466701U001 AH466704U001 AH466703U002 CF466796U016
590P/0380/220/ AH466701U001 AH466704U001 AH466703U002 CF466796U016
591P/0500/220/ AH466701U001 AH466704U001 AH466703U002 CF466768U016
590P/0500/220/ AH466701U001 AH466704U001 AH466703U002 CF466768U016
591P/0725/220/ AH466701U001 AH466704U001 AH466703U002 CF466697U016
590P/0725/220/ AH466701U001 AH466704U001 AH466703U002 CF466697U016
591P/0830/220/ AH466701U001 AH466704U001 AH466703U002 CF466767U016
590P/0830/220/ AH466701U001 AH466704U001 AH466703U002 CF466767U016
591P/0380/500/ AH466701U002 AH466704U001 AH466703U002 CF466796U016
590P/0380/500/ AH466701U002 AH466704U001 AH466703U002 CF466796U016
591P/0500/500/ AH466701U002 AH466704U001 AH466703U002 CF466768U016
590P/0500/500/ AH466701U002 AH466704U001 AH466703U002 CF466768U016
591P/0725/500/ AH466701U002 AH466704U001 AH466703U002 CF466697U016
590P/0725/500/ AH466701U002 AH466704U001 AH466703U002 CF466697U016
591P/0830/500/ AH466701U002 AH466704U001 AH466703U002 CF466767U016
590P/0830/500/ AH466701U002 AH466704U001 AH466703U002 CF466767U016
591P/0380/600/ AH466701U003 AH466704U002 AH466703U002 CF466796U018
590P/0380/600/ AH466701U003 AH466704U002 AH466703U002 CF466796U018
591P/0500/600/ AH466701U003 AH466704U002 AH466703U002 CF466768U018
590P/0500/600/ AH466701U003 AH466704U002 AH466703U002 CF466768U018
591P/0725/600/ AH466701U003 AH466704U002 AH466703U002 CF466697U018
590P/0725/600/ AH466701U003 AH466704U002 AH466703U002 CF466697U018
591P/0830/600/ AH466701U003 AH466704U002 AH466703U002 CF466767U018
590P/0830/600/ AH466701U003 AH466704U002 AH466703U002 CF466767U018
Frame 5 Fitted with the 590PD Door Assembly LA466454U002 containing the Control Board
Product Power Board Suppression Board Trigger Board Slave Power
591P/1580/220/ AH466701U001 AH466704U001 AH466703U002 * AH466706U001
590P/1580/220/ AH466701U001 AH466704U001 AH466703U002 * AH466706U001
591P/1580/500/ AH466701U002 AH466704U001 AH466703U002 * AH466706U002
590P/1580/500/ AH466701U002 AH466704U001 AH466703U002 * AH466706U002
591P/1580/600/ AH466701U003 AH466704U002 AH466703U002 * AH466706U003
590P/1580/600/ AH466701U003 AH466704U002 AH466703U002 * AH466706U003
Frame H Fitted with the 590PXD Door Assembly LA466454U001 containing the Control Board and Adaptor Board AH466405U001
Product Power Board Trigger Board Suppression Board Snubber Board
591P/1200/500/ AH466001U101 AH466003U001 AH466003U003 AH466004U001
590P/1200/500/ AH466001U101 AH466003U001 AH466004U001
591P/1700/500/ AH466001U101 AH466003U001 AH466003U003 AH466004U001
590P/1700/500/ AH466001U101 AH466003U001 AH466004U001
591P/2200/500/ AH466001U101 AH466003U101 AH466003U103 AH466004U101
590P/2200/500/ AH466001U101 AH466003U101 AH466004U101
591P/2700/500/ AH466001U101 AH466003U101 AH466003U103 AH466004U101
590P/2700/500/ AH466001U101 AH466003U101 AH466004U101
591P/1200/690/ AH466001U001 AH466003U002 AH466003U004 AH466004U002
590P/1200/690/ AH466001U001 AH466003U002 AH466004U002
591P/1700/690/ AH466001U001 AH466003U002 AH466003U004 AH466004U002
590P/1700/690/ AH466001U001 AH466003U002 AH466004U002
591P/2200/690/ AH466001U001 AH466003U102 AH466003U104 AH466004U102
590P/2200/690/ AH466001U001 AH466003U102 AH466004U102
591P/2700/690/ AH466001U001 AH466003U102 AH466003U104 AH466004U102
590P/2700/690/ AH466001U001 AH466003U102 AH466004U102
Keypad 6901 and Keypad 6911
Parker DC Drives 590P & 591P
Based on 40 years application experence all over the world.Parker design dc drives to help its clients improve productivity and reduce energy consumption. Currently,Parker has designed DC590+ Integrator Series 2 Digital DC Drive.The DC590+ dc drives use an advanced control platform to supply very good flexibility and performance.
DC590+ Drives have 590P 4 quadrant regenerative drive and 591P 2 quadrant non-regenerative drive.These two types are all good performance.Their current range from 15A to 2700A.Voltage range from 220V-500V(±10%) 50/60Hz,and 400V-690V(±10%) 50/60Hz option.
ELECTRICAL PARAMETERS
Current Rating:
Frame 1 : 15A , 35A
Frame 2 : 40A , 70A , 110A , 150A , 165A
Frame 3 : 180A , 270A
Frame 4 : 380A , 500A , 725A , 830A
Frame 6 : 1250A , 1600A , 1950A
Frame H : 1200A , 1700A , 2200A,2700A
Input Voltage
Three phase AC 230V | Three phase AC 380-480V | Three phase AC 500-690V
Output Power (HP)
1 – 2000HP
Communication Interface
RS232 | RS485 | CANopen | Modbus | Profibus | Ethernet TCP / IP
CERTIFICATES
CE (EMC & LVD) | cUL Listed | UL Listed |
Feedback options
Armature Voltage | Encoder |Tachometer
Operating temperature
Frame : 1-2 0-45C | Frame 3-H : 0-40C
Overload value
150 % for 30s | 200% for 10s | Higher ratings with reduced overload are available
Parker 590 DC Drives Part Numbers list:
Part No. | Current | Power | Part No. | Current | Size(mm) |
590P/15A | 15A | 7.5KW | 591P/15A | 15A | 200*375*220 |
590P/35A | 35A | 15KW | 591P/35A | 35A | 200*375*220 |
590P/40A | 40A | 18.5KW | 591P/40A | 40A | 200*434*292 |
590P/70A | 70A | 30KW | 591P/70A | 70A | 200*434*292 |
590P/110A | 110A | 45KW | 591P/110A | 110A | 200*434*292 |
590P/165A | 165A | 60KW | 591P/165A | 165A | 200*434*292 |
590P/180A | 180A | 75KW | 591P/180A | 180A | 250*485*234 |
590P/270A | 270A | 110KW | 591P/270A | 270A | 300*485*234 |
590P/380A | 380A | 160KW | 591P/380A | 380A | 253*700*358 |
590P/500A | 500A | 200KW | 591P/500A | 500A | 253*700*358 |
590P/725A | 725A | 300KW | 591P/725A | 725A | 253*700*358 |
590P/830A | 830A | 315KW | 591P/830A | 830A | 253*700*358 |
590P/1580A | 1580A | 600KW | 591P/1580A | 1580A | 506*700*358 |
590P/2200A | 2200A | 830KW | 591P/2200A | 2200A | 850*1406*417 |
590P/2700A | 2700A | 1000KW | 591P/2700A | 2700A | 850*956*417 |
Parker 590 Power Bridge:
590P : 4 Quadrant Regenerative DC Drives : Dual Three Phase SCR bridges
591P : 2 Quadrant Non-Regenerative DC Drives: Single SCR bridge
Parker dc drives 590 15A-2700A Framework,Frame 1- Frame 6
Eurotherm Drives 590C & 591C
Eurotherm 590C & 591C are digital dc drives,designed for use in a suitable enclosure,with associated control equipment.590+ DC drives have two type models,590C DC Drives and 591C DC Drives,590C is 4Q reversible DC drive,and 591C is 2Q no-reversible DC drive.Their current range from 15A to 720A.Voltage range from 220V-500V(±10%) 50/60Hz.
Eurotherm 590 product range:
590C : Three phase 4 quadrant regenerative converter up to 720A
591C : Three phase 2 quadrant non-regenerative converter up to 720A
Eurotherm 590 series part number table:
Part No. | Current | Power | Part No. | Current | Size(mm) |
590C/35A | 35A | 15KW | 591C/35A | 35A | 250*415*180 |
590C/70A | 70A | 30KW | 591C/70A | 70A | 250*415*180 |
590C/110A | 110A | 45KW | 591C/110A | 110A | 250*445*180 |
590C/150A | 150A | 60KW | 591C/150A | 150A | 250*445*180 |
590C/180A | 180A | 75KW | 591C/180A | 180A | 250*555*180 |
590C/270A | 270A | 110KW | 591C/270A | 270A | 300*500*210 |
ELECTRICAL PARAMETERS
Power supply 3 Phase*220-500VAC(±10%)
Output voltage value 35 – 720A
Power (KW) 15– 250KW
Feedback options Encoder | Armature Voltage | Tachometer
Communication RS232 / RS485 |Profibus | Modbus
OPERATING CONTROL MODES Regenerative | Non-Regenerative | Stack Controller
OPERATING TEMPERATURE (C) 0-45C (15-165A) / 0-35C (180-270A) / 0-40C (380-2700A) / derate up to 55C max
OPERATING TEMPERATURE (F) 32-113F (15-165A) / 32-95F (180-270A) / 32-104F (380-2700A) / derate up to 131F max
Eurotherm 590 series outline drawing:
Parker SSD DC Drives 514C & 512C
The 514C controller is intended for use in an Industrial Environment, it should be mounted within an enclosure which provides protection to the controller and the user.
The controller should be permanently earthed at the terminals provided.
The 514C controller is designed to control the speed of a DC Shunt wound or permanent magnet motor. It will provide control of the motor speed in all 4 Quadrants of operation.
The controllers are designed to operate from a single phase AC mains supply in the range of 110 Vac to 415 Vac at 50 or 60 Hz. An auxiliary supply is required for internal power supply generation and main supply contactor sequencing. Coding is derived from the main power terminals and is functional over the whole input voltage range.The Speed of the DC Motor is controlled using a linear closed loop system with a feedback signal from either tachogenerator or armature voltage, the feedback source being switch selectable.A current loop within the speed loop always ensures that controlled levels of current are applied to the motor, actual levels being scaleable via programmable switches.Motor protection is provided by a Stall detection circuit which will remove current from the motor after approximately 60 seconds.Controller protection is provided by an Instantaneous Overcurrent trip circuit overriding control in the event of a Short Circuit.
Technical Specification
AC Supply Voltage Single Phase 110V-480V ;50-60Hz
Current Rating 4A / 8A / 16A / 32A
Overload 150% for 60 seconds
Voltage selection Jumper selection of supply voltage
Speed Control 20:1 (arm v f/b),100:1 (tach fb)
Digital Inputs Run,Enable,Stall override
Digital Outputs Drive health
OPERATING ALTITUDE Up to 1000m ASL
Parker 514C & 512C Part Number:
Part No. | Current | Part No. | Current | Part No. | Current | ||
506/3A | 3A | 512C/8A | 8A | 514C/8A | 8A | ||
507/6A | 6A | 512C/16A | 16A | 514C/16A | 16A | ||
508/12A | 12A | 512C/32A | 32A | 514C/32A | 32A |
Parker 514C 512C Power Bridge:
514C : 4 Quadrant Regenerative , Dual Three Phase SCR bridges
512C : 2 Quadrant Non-Regenerative , Single SCR bridge
Variable Field Control with SCR’s
Output Current Values:
4A / 8A / 16A / 32A
Typical applications :
- Machine tool spindles
- Wire drawing machines
- Winders/Reelers
Parker 514C 512C Installation Procedure
INSTALLATION PRECAUTIONS
Before connecting AC supplies to this equipment:
1) Ensure good airflow over the heatsink. Maintain clearance of 75mm above and below
controller. For safety maintain a clearance of 20mm at the sides of the controller.
2) Operating temperature range does not exceed 0 to +40.
3) Controller is used in a Pollution Degree 2 environment.
4) Avoid vibration.